|
Reset the B6200/B6300 back to the original default settings. Note: This will change all settings back to the defaults, it is recommended to print the current system settings before performing this procedure, by following these steps: Press Menu once. Press Down Arrow once. Press Right Arrow once. Press Down Arrow three times. Press Right Arrow once. Press Select. This will print the current settings. Step #1: Press the left and right arrow buttons for a second or so release the buttons, then press the on-line button to enter the Diag. Menu. Display: Diag. Menu Preventive Diag. Step #2: Press the down arrow button twice: Display Diag. Menu Adjustment Step #3: Press the right arrow button once: Display Adjustment DC 131 NVM R/W Step #4: Press the down arrow button once: Display Adjustment DC 301 NVM Init. Step #5: Press the right arrow button once Display Adjustment DC 301 NVM Init.SYS Step #6: Press the Feed/Select button once: Display DC 301 NVM Init. SYS* Step #7: Exit the Diag.Menu Product(s): B6200; B6200n; B6300n
|