1-800-777-8444
 Home   Store   My Account   Track Order   View Cart   Login 

Cart Contents
Items in Cart: 0
Subtotal: $ 0
[View Cart] [Check Out]

Printer Support - Help with troubleshooting laser and inkjet printers
    Clean Planet Program Clean Planet Program
    Contact Us Contact Us
    Credit Application Credit Application
    Drivers & Downloads Drivers & Downloads
    Error Codes Error Codes
    How To How To
    Knowledge Base Knowledge Base
    Laserquipt Policies Laserquipt Policies
    MSDS MSDS
    News Releases News Releases
    Print Quality Issues Print Quality Issues
    Troubleshooting Troubleshooting
    Hewlett Packard Hewlett Packard
    Lexmark Lexmark
    Oki Data Oki Data
    Other Other

    Multifunctions
    Printer Accessories
    Printer Parts
    Printers
    Ribbon Supplies
    Laser Supplies
    InkJet Supplies
    Media
    Clearance
    Advanced Search
    Support

Browsing In Home > Support > Troubleshooting > Lexmark > Clearing the Maintenance Count-Lexmark Glossary of printer troubleshooting terms Glossary Contact Us


Clearing the Maintenance Count-Lexmark

LaserPrinter 10R/10 Plus, 12 Series, 16 Series, Optra R & L Turn the printer off, hold down the READY and RETURN buttons while powering on the printer until the display reads PERFORMING SELF TEST
Select MAINTENANCE COUNT
Select RESET to return the count to zero
Press the RETURN button to return to the Diagnostics Mode main menu, then reset printer to return to normal mode


Optra S, 2420/2450/2455/3455 Turn the printer off, hold down the GO and RETURN buttons while powering on the printer until the display reads PERFORMING SELF TEST. When ready, the display will read PRINT REGISTRATION
Scroll to PRINTER SETUP and press the SELECT button
Scroll to MAINTENANCE PAGE COUNT and press the SELECT button
Scroll to RESET MAINTENANCE COUNT and press the SELECT button to reset the count to zero
Press the RETURN button to return to the Diagnostics Mode main menu, then exit Diagnostics Mode to return to normal mode


Optra T (all models)Turn the printer off, hold down the SELECT and RETURN buttons while powering on the printer until the display reads PERFORMING SELF TEST. After the self test, the display will read CONFIG MENU
Press the right arrow side of the MENU button until MAINTENANCE PAGE COUNT is on the display
Press the SELECT button. RESET should be displayed
Press the SELECT button again to reset
Press the RETURN button to return to the Configuration Menu and press the left arrow side of the MENU button to exit the Configuration Menu


Optra W810Enter hold down the SELECT and RETURN buttons while powering on the printer until the display reads PERFORMING SELF TEST. After the self test the display will read CONFIG MENU
Press the right arrow side of the MENU button until MAINT. COUNTER is displayed
Press the SELECT button, then scroll to RESET TRANSFER or RESET FUSER and press the SELECT button again to reset
Press the RETURN button to return to the Configuration Menu and press the left arrow side of the MENU button to exit the Configuration Menu


Optra C710 hold down the SELECT and RETURN buttons while powering on the printer until the display reads PERFORMING SELF TEST. After the self test the display will read CONFIG MENU
Press the MENU button right or left until RESET FUSER COUNT appears
Press the SELECT button to reset the count


Optra C720 hold GO and RETURN buttons and turn the printer on
Continue holding until PERFORMING SELF TEST is displayed
Select RESET COUNTERS from the Diagnostic Menu
Select the individual counter for reset and press the SELECT button


Optra C750 hold down the SELECT and RETURN buttons while powering on the printer until the display reads PERFORMING SELF TEST. After the self test, the display will read CONFIG MENU
Select individual reset for fuser or ITU kit


Optra SC 1275/Color 1200 Hold down the GO and RETURN keys while powering on the printer until PERFORMING SELF TEST is displayed
When REGISTRATION is displayed, press the right side of the MENU key six times until MAINTENANCE is displayed
Press the SELECT button, and then press the right side of the menu button to scroll to 80 or 81 RESET
Press the RETURN button until the display reads MAINTENANCE
Press the right side of the MENU button until the display reads EXIT DIAGNOSTICS
Press the SELECT button to return to the normal mode











Related Articles
article Clearing the Maintenance Count-HP
If the display panel on your HP laserjet reads...
  3-22-2005    Views: 4561   
article Clearing the Printer Maintenance Message
Turn the product off. Press and hold down the...
  10-21-2005    Views: 2009   
article How to reset the Transfer Unit and Fuser Count
When the Electrostatic Transport Belt (ETB) or...
  6-13-2005    Views: 7908   
article What is a Maintenance Kit?
Why do I need a maintenance kit?Although not...
  3-23-2005    Views: 2018   
article Using the Status Monitor To Display Page / Drum Count
OKI Knowledgebase Article -- How to Display the...
  10-25-2005    Views: 1766   






User Comments (0) EMAIL | PRINT
      No comments have been posted.

Article 059
Created 3-22-2005
Modified 4-25-2005
Author Ken
Rating
Rate It!



 View Item
$69.95
Reg. $324.00
78.41%
Compatible Optra™ S 1250/ 1255/ 1620/ 1625/ 1650/ 1855/ 2420/ 2450/ 2455/... ...

 more info>

add to cart>



 View Item
$70.31
Reg. $95.54
26.41%
4039/4049 Toner (OEM# 1382150) (13000 Yield) ...

 more info>

add to cart>



 View Item
$89.95
Reg. $449.00
79.97%
Compatible Optra™ T T610/ 612/ 612n/ 614/ 614n/ 616 Print Cartridge High... ...

 more info>

add to cart>



 View Item
$180.11
Reg. $234.00
23.03%
*Optra™ S 1250/ 1255/ 1620/ 1625/ 1650/ 1855/ 2420/ 2450/ 2455/ 4059... ...

 more info>

add to cart>



 View Item
$197.28
Reg. $296.00
33.35%
*Optra™ S 1250/ 1255/ 1620/ 1625/ 1650/ 1855/ 2420/ 2450/ 2455/ 4059... ...

 more info>

add to cart>



 View Item
$197.30
Reg. $296.00
33.34%
*Optra™ S 1250/ 1255/ 1620/ 1625/ 1650/ 1855/ 2420/ 2450/ 2455/ 4059... ...

 more info>

add to cart>



 View Item
$232.50
Reg. $268.00
13.25%
4039-10+/ 4049 Optra™ Lxn+/ L/ Lx/ Lxi/ Lxi+/ R/ RX/ RT+/ RN+/ 3112 Model 1/... ...

 more info>

add to cart>



 View Item
$233.88
Reg. $328.00
28.70%
Optra™ S 1250/ 1255/ 1620/ 1625/ 1650/ 1855/ 2420/ 2450/ 2455/ 4059 Toner... ...

 more info>

add to cart>



 View Item
$234.95
Reg. $281.00
16.39%
4039/ / 3912/ 3916 Laser Printer Toner Cartridge (7 000 Yield) ...

 more info>

add to cart>



 View Item
$235.65
Reg. $228.00
-3.36%
Optra™ T T610/ 612/ 612n/ 614/ 614n/ 616 Return Program Print Cartridge (10... ...

 more info>

add to cart>










.: Powered by Lore 1.5.4
Home  |   Privacy  |   Terms  |  
Copyright © 2003 LaserQuipt.com