When the time to replace the transfer belt unit is reached, the message TRANSFER END appears. Printing can continue even after this message appears; however, since the print quality is reduced, the transfer belt unit should be replaced immediately. Konica 1710592-001 1. Open the printer’s front cover. 
2. Turn the dial to unlock the waster toner bottle. 
3. Pull out the waste toner bottle and the toner cartridges for about 10 cm (4 inches). 
4. Using a coin, remove the screws on the left side cover. Be careful not to lose the screws. 
5. Remove the left side cover. 
6. Open the right side cover, and then use a coin to loosen the screws securing the transfer belt unit. 
7. From the side where the left side cover was removed, hold the arm, and then carefully pull out the transfer belt unit. 
8. Prepare a new transfer belt unit. Be careful not to touch the surface of the belt. 
9. Insert the new transfer belt unit along the rails. 
10. Fully insert the transfer belt unit. 
11. From the right side cover side, tighten the screws to secure the transfer belt unit and then close the right side cover. 
12. Insert the waste toner bottle and the toner cartridges all the way in until they snap into place. 
13. Turn the dial to lock the waste toner bottle into place. 
14. Attach the left side cover, and then tighten the screws. 
15. Close the front cover. 
16. Reset the counter in the printer panel menu. A. Press the Menu Select button. B. Press the Right Arrow button until you see ENGINE. C. Press the Menu Select button. D. Press the Right Arrow button until you see SERVICE. E. Press the Menu Select button. F. Press the Right Arrow button until you see RESET COUNTER TRANSFER UNIT. G. Press the Menu Select button. H. Press the Up Arrow until you see READY. 
|